Hitachi Energy Analogue Output Module 520AOD01

Applications

Analogue control outputs for sequential or closed-loop control, display instruments, measurement recorders, etc,

The analogue output board 520AOD01 can be connected to measuring and recording instruments, etc.

The board 520AOD01 has 2 output channels which can be www.abb-drive.com configured for different voltage or current output ranges.

The module 520AOD01 can process the following types of signals:

– Analogue setpoint commands

– Floating-point setpoint commands

The following output ranges can be configured independently for each channel via on-board switches:

– ± 2.5 mA

– ± 2.5 mA ± 5 mA

– ± 10 mA

– ± 20 mA (4…20 mA) .20 mA)

– ± 1.25 VDC

– ± 2.5 VDC

– ± 5 V DC

– ± 10 V DC

Output formats unipolar, bipolar or real-time zero (4 … 20 mA) are configurable via software parameters. 20 mA) can be configured via software parameters.

Characteristics

Analogue outputs

Each output has a digital-to-analogue converter (DAC) for converting digital values into analogue signals. the resolution of the DAC is 11 bits plus sign.

The received output value is stored until a new value is received. The output channels are set to 0 % after powering up or restarting the communication module.

The output channels are isolated from the power supply, but not between the two channels.

Power input

The power required by the module is supplied through the RTU520 I/O bus connector. In addition, 24 VDC (UE) is required (e.g. from the 560PSU40/41).

The UE voltage must be supplied externally and connected to the UE connector.

I/O Controller (IOC)

The microcontroller on the module handles all key tasks of the parameterised processing functions. In addition, it communicates interactively with the RTU I/O bus.

All configuration data and processing parameters are loaded by the communication unit via the RTU I/O bus.

The module is connected to the RTU520 I/O bus by connecting it to an I/O adapter (e.g. 520ADD01) or to the RTU520 communication unit.

During initialisation and operation, the module performs a series of tests. If a fault occurs, it will be reported to the communication unit.

All fault conditions affecting the module’s functionality are signalled as common faults by means of red LEDs. Module faults are detected by the communication unit.

Hitachi Energy 520AID01 Analogue Input Module

Applications

The 520AID01 module records up to 6 analogue measured values.

The module 520AID01 can process the following types of signals

Signals:

– Analogue measured values (AMI)

– Floating-point measurement information (MFI)

The following measurement ranges can be configured

520AID01 R0001:

– ± 2.5 mA

– ± 5 mA

– ± 10 mA

– ± 20 mA

The following measurement ranges can be configured as

520aid01 r0002:

– ± 1 V DC

– ± 10 V DC voltage

Additional valid ranges and real-time zero signals can be generated beyond these ranges by means of conversions in the communication unit (CMU).

The module is available in two versions (rubrics):

– R0001: Current measurement version

– R0002: Voltage measurement version

Characteristics

Analogue inputs

Basic signal checking and cycle processing functions can be done locally to reduce the burden on the communication unit.

The module transmits the relevant changes as events via the RTU I/O bus.

The 6 differential inputs are not galvanically isolated from the power supply.

The single-ended or differential inputs have a resolution of up to 2048 levels (11 bits plus sign) and measure amplitudes of 100 per cent.

The differential inputs are protected against static and dynamic overvoltage by means of a protection circuit. A low-pass filter suppresses unwanted frequency components.

The internal high resolution of the AD converter allows all measurement ranges to be scanned with the same resolution.

An additional 2 measurement channels are used for automatic zero www.abb-drive.com calibration. This compensates for long-term component drift.

In order to eliminate tolerances, calibration is carried out during production.

Measurement ranges and line frequencies can be easily configured with the RTUtil500 configuration tool.

The synchronisation of the scan period with the line frequency enhances the line frequency interference suppression of DC input signals.

Power input

The required power supply for the module is provided via the RTU520 I/O bus connector.

I/O Controller (IOC)

The microcontroller on the module handles all key tasks for the parametric processing functions.

In addition, it communicates interactively with the RTU I/O bus.

All configuration data and processing parameters are loaded by the communication unit via the RTU I/O bus.

The module can be connected to the RTU520 I/O bus by connecting an I/O adapter (e.g. 520ADD01) or the RTU520 communication unit.

The analogue input unit performs the following processing functions on the measured values:

– Scan period and line frequency interference suppression

– Zero value monitoring and switch detection

– Smoothing

– Absolute or cumulative threshold monitoring

– Periodic transmission and background cycling

During initialisation and operation, the module performs a series of tests. If a fault occurs, it will be reported to the communication unit.

All fault conditions affecting the module’s functionality are indicated as common fault signals by means of red LEDs.

Hitachi Energy 520BOD01 Binary Output Module

Applications

The binary output module 520BOD01 controls 8 binary process signals via relay contacts.

The output signals can be assigned to process functions according to www.abb-drive.com configuration rules.

The module 520BOD01 can process the following types of signals:

– Single or dual command (SCO or DCO), 1-pole or 2-pole outputs, no checksum (n select 1).

– Single or dual commands (SCO or DCO) with 1.5- or 2-pole output, no checksum (1 of n) Single or dual commands (SCO or DCO) with 1.5- or 2-pole output, no checksum (1 of n)

– Adjustment Step Command (RCO), 1 or 2 poles

– Digital Setpoint Command, 8-bit, No Strobe (DSO8)

– Digital setpoint command, 8-bit, no strobe (DSO8) Bit-string output, 1 or 8-bit (BSO1 or BSO8)

Modules allow switching voltages up to 150 V DC or up to 8 A continuous current. 8 A continuous current.

Characteristics

Binary Outputs

The binary outputs are relay contacts.

The 8 outputs are isolated from each other. In addition, they are isolated from the internal electronics by means of an optocoupler.

All 8 relay contacts have independent outputs and there are no common circuits.

The command outputs to the process equipment can be executed either directly or in conjunction with the command output monitoring module.

The Command Output Monitoring Module checks the output circuits (1 out of n times). For more details, refer to the Command Output Monitor data sheet.

The following modules with command output monitoring functions are supported:

– 560CIG10

– 560CID11

– 520CSD01

The 1.5-pole command output can only be used in conjunction with the command output monitor module. When using the 1.5-pole command output

One of the output relays of the 520BOD01 switches the command to the intermediate relay. The process voltage of the intermediate relay is switched by the command output monitoring module.

For bipolar commands, two output relays are required per command.

Before and during command output, the module 520BOD01 performs several command monitoring functions.

These tests ensure correct output. These tests can be further improved with the command output monitoring module.

If a fault is detected by the command monitoring, the command is cancelled.

Power input

The required power supply for the module is provided via the RTU520 I/O bus connector. In addition, 24 VDC (UE) is required (e.g. from the 560PSU40/41).

The UE voltage must be supplied externally and connected to the UE connector.

Input/Output Controller (IOC)

The microcontroller on the module handles all key tasks for the parameterised processing functions. In addition, it communicates interactively with the RTU I/O bus.

All configuration data and processing parameters are loaded by the communication unit via the RTU I/O bus.

The module can be connected to the RTU520 I/O bus by connecting it to an I/O adapter (e.g. 520ADD01) or to the RTU520 communication unit.

The binary output unit can perform the following processing functions for each signal type:

– Control of the command output duration

Command monitoring function:

– Checking of the output relays on the module (m out of 16)

– Monitoring of the output bit pattern by reading back the output status

– Monitoring of the switching voltage (24 V DC coil voltage) before and during output, only with the control module (1 of n)

– Command output duration monitoring

During initialisation and operation, the module performs a series of tests. If a fault occurs, it is reported to the communication unit.

All fault conditions affecting the function of the module are signalled as common faults by means of red LEDs. Module faults are detected by the communication unit.

Hitachi Energy 520BID01 Binary Input Module

Applications

The module 520BID01 provides 16 galvanically isolated inputs for up to 16 binary process signals.

The input signals are scanned and processed with a time resolution of up to 1 ms. The input signals can be assigned to processing functions according to configuration rules.

The input signals can be assigned to processing functions according to configuration rules.

The module 520BID01 can process the following types of signals or combinations of signals:

– 16 time-stamped single-point messages (SPI)

– 8 time-stamped double-point messages (DPI)

– 2 8-bit digital measured values (DMI8)

– 1 16-bit digital measurement (DMI16)

– 16 integrated totals (max. 25 Hz) (ITI)

– 2 step position information, 8 bits each (STI)

– 2 bit string inputs, 8 bits each (BSI8)

– 1 16-bit bit string input (BSI16)

– or a combination of these signal types

The module is available in two versions (rubrics):

– 520BID01 R0001: Process voltage 24 to 60 VDC.

There are LEDs for each input and a common loop for each of the 8 inputs.

– 520BID01 R0002: Process voltage 110 to 125 V DC.

Each input is signalled by an LED and each of the 8 inputs has a common loop.

 

Characteristics

Binary inputs

The inputs are galvanically isolated by means of optocouplers. 8 input channels are grouped together and have a common loop.

The binary input channels are protected against reverse voltage. If the input signal is of the wrong polarity, the input current will be zero.

There are 16 LEDs on the module to indicate the signal status of the inputs.

The LEDs are switched by the controller.

The maximum permissible frequency of the counter pulses is 25 Hz.

Power input

The power required by the module is supplied via the RTU520 I/O bus connector.

I/O controller (IOC)

The microcontroller on the module handles all time-critical tasks www.abb-drive.com of the parameterised processing function.

The microcontroller on the IOC module handles all time-critical tasks of the parameterised processing functions. In addition, it

communicates interactively with the RTU I/O bus.

All configuration data and processing parameters are loaded by the communication unit via the RTU I/O bus.

The communication unit loads all configuration data and processing parameters via the RTU I/O bus when communicating with an I/O adapter (e.g. 520ADD01) or a

module is connected to the RTU520 I/O bus.

The binary input unit performs the following processing functions

Processing functions for different types of signals:

– Digital filtering and suppression of contact jumps

– Validity check and suppression of intermediate input states

Digital filtering, suppression of contact jumps Validity check and suppression of intermediate input states

– Consistency check for all channels assigned to digital measurement values or step position information

– Summing of incremental pulses to form a combined total in a register with 31-bit resolution.

Formation of combined totals in registers with 31-bit resolution

– Copy the combined total into the freeze register for

Data Retention

The module provides a data buffer for temporary storage of up to 50 event messages, including timestamps.

Up to 50 event messages including timestamps.

Stored in chronological order for transmission to the communication unit (CMU).

During initialisation and operation, the module performs a series of tests.

If a fault occurs, it is reported to the CMU. All fault conditions affecting the function of the module are

be signalled as general faults by the red LED.

Module faults are detected by the communication unit.

Hitachi Energy 520PSD01 Power Supply Unit

DIN rail mounted base module RTU520:

Input voltage: 24 VDC, 20 W

Natural convection cooling

Reverse voltage protection

LEDs for monitoring the output voltage

Available with up to 16 RTU520 IO modules

Efficiency: 85 per cent

Features

The Power Supply Unit 520PSD01 has the following features and functions:

– Natural convection cooling

– Electronic power limiting at the outputs

– Short-circuit protection at the output

– Input overvoltage protection

– Reverse voltage protection on inputs

– Potential-free isolation between inputs and outputs

– LEDs to monitor output voltage

When interacting with the 520CMD01. the input voltage (24 VDC) passes through the I/O module.

During power-up, the 520CMD01 switches the 24 V output voltage to the active voltage of the I/O module.

Applications

The Power Supply Unit 520PSD01 generates or switches 24 VDC, ±15 VDC, and 5 VDC for RTU520 systems.

The output power is sufficient to power an RTU520 with up to 16 I/O modules. The input voltage to the power supply unit is 24 VDC.

Hitachi Energy Communication Unit 520CMD01

Applications

The 520CMD01 Communication Unit is the CMU module of the RTU520 product family.

Its main tasks are

– Managing and controlling the RTU520 I/O modules via the serial I/O bus.

– Reading process events from the input modules.

– Sending commands to the output modules.

– Communication with the control system and the local HMI system via the www.abb-drive.com serial interface (RS232) and the Ethernet 10/100BaseT interface.

– Communicates with sub RTUs, IEDs or multimeter devices via interface (RS485).

Communicates with sub-RTUs, IEDs, or multimeter devices through an interface (RS485).

– Manages the time base station and synchronisation I/O modules of the RTU520 product line.

– Handles the dialogue between the RTU520 product line via the LAN interface and the RTU520 product line via the LAN interface and a web browser.

The communication unit is mounted on a DIN rail together with the power supply and I/O modules.

The communication unit handles communication protocols based on Ethernet and UART characters.

The unit is available in two versions

– R0001: Real-time clock without battery buffer (RTC)

– R0002: Real-time clock with battery buffer (RTC)

Features

A real-time operating system is implemented by applying the ARM9 controller AT91SAM9260.

520CMD01 is responsible for interface management, event processing, time base and internal database.

The 520CMD01 is responsible for interface management, event processing, time base and internal database. The controller acts as a master for the serial I/O bus (WRB).

System-related configuration files are stored on a non-volatile flash memory card (Removable SD Card™).

to ensure that the system configuration is valid after a power-on reset (PoR).

An optional battery-buffered RTC is used to maintain accurate time in the event of a power failure.

The communication unit provides the following interfaces:

– Communication Port 1 (CP1): RS232C serial interface with RJ45 connector.

– Communication ports 2 and 3 (CP2 and CP3): RS485 serial interface with RJ45 connector.

– Ethernet Interface (E1): 10/100BaseT with RJ45 connector.

– Interface X1 for power supply to the power supply unit 520PSD01.

– Interface X2 for communication with the RTU520 I/O module.

– USB 2.0 device interface for diagnostics and maintenance.

– WRB I/O bus interface for local communication with the I/O module.

Hitachi Energy Cold Shrink Fittings and Terminals JS-A and CST (12-42 kV)

Cold Shrink Fittings JS-A 12-42 kV

Application

Cold-shrinkable joints for 12-42 kV XLPE-insulated single- or three-core cables with aluminum or copper conductors.

Standards

– GB/T 12706.4

– IEC 60502.4

Characteristics

– The body of the cold shrink fitting is made of liquid silicone rubber, which is water-repellent and erosion-resistant. High elasticity and shrinkage capacity ensures a strong and stable active pressure between the rubber and the cable, which can cope with the expansion or contraction of the cable diameter in the process of changing

Expansion or contraction of the cable diameter under load cycling.

– The strain relief cone, insulation and conductive layers are pre-molded together in a one-piece design, eliminating the need for installation tools. This solves problems such as poor bonding between the separate layers and ensures safe operation.

– Unique multi-layer waterproof construction. Waterproof armored tape and resin outer jacket solutions are available

Cold shrink termination CST 12-42 kV

Applications

Cold shrink cable termination for 12-42 kV XLPE and EPR insulated single or three core cables with aluminum or copper conductors.

Suitable for installations at high altitudes, in humid or heavily polluted environments.

Standard

– GB/T 12706.4

– IEC 60502.4

Features

– Cold-shrinkable cable terminations are made of liquid silicone rubber, which is resistant to aging, UV, humidity, tracking and erosion. The high elasticity and shrinkage capacity ensures a strong and constant active pressure between the rubber and the cable, which can cope with the

expansion or contraction of the cable diameter during the load cycle.

– The geometric field control in the stress cone is integrated into the termination body, effectively dispersing the high electrical stresses at the stripping location of the cable screen.

CST 12-42 kV

– The terminations are supplied in www.abb-drive.com kits for single or three-core cables. The kits include copper tape and a constant force spring for the ground connection. 3-core cable kits also include crutch seals and cold-shrink protective hoses.

Hitachi Energy Shielded Detachable Connectors

Connecting Cable Networks Safely and Reliably

Hitachi Energy is committed to building reliable and secure power transmission and distribution networks. To fulfill this commitment, we offer a wide range of cable accessories to customers in the power generation and transmission utility, renewable energy, and industrial sectors.

Shielded Separable Connectors

Applications

Separable cable connectors with shield are used for 12-24 kV XLPE-insulated single- or three-core cables with aluminum or copper conductors. They are suitable for use in standardized bushings with an A-type outer cone according to EN 50181.

Standards

– GB/T12706.4

– IEC 60502.4

Features

– Elbow cable connectors CSEB and straight cable connectors CSS-B are made of EPDM rubber with three layers: conductive inner layer, insulating layer and conductive outer layer.

The three layers of rubber are vulcanized to make the interface between the layers as perfect as possible. It has good UV, ozone and tracking resistance and is suitable for outdoor use.

The capacitance test points of the connectors are covered by conductive rubber caps to ensure complete shielding.

– Supplied in a three-phase kit including crimped cable lugs, terminal block, installation tool and ground wire, designed to ensure reliable installation

– Single- or three-conductor cable grounding kit must be used (can be ordered separately)

Pre-assembled shielded detachable connectors

Applications

Preformed shielded breakaway connectors for 12kV XLPE insulated single or three core cables with aluminum or copper conductors. Suitable for EN 50181 Type C interface

Standard

– GB/T12706.4

– IEC 60502.4

Features

– Pre-molded shielded separable connectors are made of EPDM rubber with three layers: conductive inner layer, insulating layer and conductive outer layer.

The three layers of rubber are vulcanized to make the interface between the layers as perfect as possible. It has good resistance to UV, ozone and tracking.

– Supplied in three-phase kits with crimped cable lugs, stress-graded adapters designed to ensure reliable installation

– Single- or three-pole cable grounding kit must be used (can be ordered separately)

Preformed shielded detachable connectors

Applications

Preformed shielded breakaway connectors for 12kV XLPE insulated single or three core cables with aluminum or copper conductors. Suitable for EN 50181 Type C interface

Standard

– GB/T12706.4

– IEC 60502.4

Features

– Pre-molded shielded separable connectors are made of EPDM rubber with three layers: conductive inner layer, insulating layer and conductive outer layer.

The three layers of rubber are vulcanized to make the interface between the layers www.abb-drive.com as perfect as possible. It has good resistance to UV, ozone and tracking.

– Supplied in three-phase kits with crimped cable lugs, stress-graded adapters designed to ensure reliable installation

– Single or three core cable grounding kit must be used (can be ordered separately)

Quality Assurance

We are committed to providing the best possible products and services. Our products meet or exceed the latest international standards.

In addition to type testing in independent laboratories, our certified design and manufacturing processes provide assurance of the highest quality. We are ISO 9001:2015 certified.

Sustainability

For Hitachi Energy, sustainability is about striking a balance between economic success, environmental stewardship and social progress that benefits all of our stakeholders.

Sustainability considerations include how we design and manufacture our products, what we offer our customers, how we work with our suppliers, the

how we assess risks and opportunities, and how we behave and relate to each other in the communities where we operate.

We also work to ensure the health, safety and security of our employees, contractors and others affected by our activities.

We are certified to ISO 14001:2015. ISO 45001:2018 and ISO 50001:2018.

Hitachi Energy New Generation Digital Substation

The term “digital substation” currently applies to substations using process bus technology. Process buses replace hard-wired connections with Ethernet communication.

Distributed intelligent electronic devices (IEDs) interconnected via a communication network based on IEC 61850 perform operation and control.

IEDs can measure and communicate variables such as current or voltage, or switching devices such as relays.

However, IEDs communicate digitally over serial or Ethernet networks for protection, measurement, metering, or monitoring.

Digital substations can use other communication methods, but IEC-61850 is the modern global communication protocol.

IEC 61850 is more than just a protocol, or even a set of protocols, it is a comprehensive standard that

It is a comprehensive standard that was designed from the ground up to operate on modern network technologies. It provides functionality not found in traditional communication protocols.

It provides interfaces to communication services and supports Generic Object Oriented Substation Events (GOOSE), Sampled Measured Values (SMV), logging and other services.

These unique features of IEC 61850 help to significantly reduce the costs associated with power system design, installation, commissioning and operation.

Asset Performance Management (APM) Solution Collects Data from Digital Substations

The Asset Performance Management (APM) solution collects data from digital substations and combines data collection, integration, visualization, and analytics to

APM encompasses concepts such as condition monitoring, predictive forecasting, and reliability-centered maintenance (RCM).

Digital Substation APM collects data from the substation’s IED and combines this data with other relevant asset data.

Combining data collection with a deeper understanding of an asset’s operating characteristics can provide significant value to operations and maintenance personnel by supporting predictive methods.

Managing Grid Assets in the Digital Substation

So how can you control the grid in a way that improves reliability and keeps the cost of power low? With limited capital budgets, the

utilities must make choices related to long-term expenditures.

These choices include

 Considering all relevant factors, determining which projects minimize risk

 Determining which aging equipment assets can more cost-effectively reduce risk

 determining whether additional capital expenditures can be justified to regulators or other stakeholders.

Regulators or other stakeholders

 Determine the most efficient way to deploy resources during an outage

Process bus digital communication standards support interoperability between IEDs from different vendors and “digitize” modern substations.

When process bus devices are properly configured according to the IEC 61850 standard, they provide fast, reliable and secure communications that

to support device protection, remote monitoring and remote control. Process buses can also provide control centers with situational awareness based on accurate and timely measurement data from all corners of the grid.

control center situational awareness based on accurate and timely measurement data from all corners of the grid. By connecting the data to the APM application, the data enables coordination between transmission sections and between transmission and distribution operators.

Hitachi ABB Power Grid APM

New asset performance management capabilities that connect directly to digital substations are expected to support all three priorities for the grid: high reliability, low cost and compliance.

However, developing a viable APM solution for the grid requires both significant domain expertise for these types of assets, as well as an understanding of these assets as a system.

It also requires a thorough understanding of how these assets work together as a system. Mathematical models based on first principles.

Simulating asset behavior in conjunction with operational statistics is a key approach to creating digital twins. A digital twin refers to a dynamic digital replica of the actual physical asset

and how it interacts with the larger grid and operators.

A digital twin refers to a dynamic digital replica of an actual physical asset and how it interacts with the larger grid and the humans who operate and maintain it.

The digital twin can include the spatial geometry of the asset and its location in the grid, as well as thermodynamic and electrical behavior.

APM, when applied effectively, can reduce OPEX and CAPEX based on predictive and prescriptive analytics, resulting in operational cost savings and/or deferring capital investment requirements.

APM can also help utilities achieve compliance as outages are reduced.

As ARC learned, Hitachi ABB Power Grid’s APM solution is designed to provide asset health and performance insights that

to help prevent critical failures while optimizing asset lifecycle costs. The solution utilizes digital twin technology, integrating online data with existing historical data.

It can also connect from the substation to the cloud using state-of-the-art IIoT (Industrial Internet of Things) connectivity technology, enabling utilities to leverage their online and offline data to

Drive a smarter, condition- and risk-based approach to asset management. By combining data collection, integration, visualization and analytics capabilities, the

utilities can gain new insights through a predictive, prescriptive and predictive view of their systems.

The solution complies with key industry standards such as ISO 55000 and PAS 55.

Hitachi ABB Power Grid APM helps utilities understand when faults are likely to occur and the consequences of those faults.

With this information, utilities are better able to achieve key objectives, including

 Cost-effectively manage asset health

 Effectively address identified risks

 Prioritizing repair and replacement decisions

 Implementing “what-if” analysis and contingency planning programs

Hitachi ABB Power Grid

Founded in 2020. Hitachi ABB Power Grid is a global technology leader with a history spanning nearly 250 years.

Headquartered in Switzerland, the company serves utility, industrial and infrastructure customers across the entire value chain.

With expertise in emerging areas such as renewable energy integration, energy storage, electrified mobility and smart cities, Hitachi ABB Power Grid is well-positioned to help companies around the world transition to a smart and distributed energy future.

Search for products

Back to Top
Product has been added to your cart