The PROFIBUS DPV1 master module is a powerful communication interface for Quantum ® processors.
Developed under licence from Quantum ®, the module uses proprietary backplane technology to enable powerful data exchange with the processor.
The module supports the full master specification according to IEC 61158. The ability to transfer acyclic parameter data via Class 1 or Class 2 DPV1 services.
Enables the processor to easily communicate with slave devices that support the PROFIBUS DPV0/V1 protocol.
This module is the input/output module between the PROFIBUS www.abb-drive.com network and the processor. The processor data transfer is asynchronous to the I/O data transfer on the PROFIBUS network.
Features Benefits
Easy to configure and manage ♦ Includes ProSoft Configuration Builder software for designing, configuring, and monitoring PROFIBUS networks
PROFIBUS DPV1 Master FDT (Field Device Tool) Communication DTM (PROFIBUS comDTM) software included.
(PROFIBUS comDTM) software for connecting any compatible FDT software container, FDT device DTM, and applicable PROFIBUS slave devices
Configuration of PTQ modules and PROFIBUS networks via Ethernet
Industry Recognition ♦ Schneider Electric CAPP (Collaborative Automation Partner Programme) certification
PROFIBUS Trade Organisation (PTO) certified
Rugged and reliable ♦ Modules built on Siemens ASIC ASPC2 Step E and Infineon C165 microprocessors
Firmware can be quickly upgraded
Compliant with Unity HEC Hot Standby feature specification.
Supports up to 6 PTQ-PDPMV1 modules per rack (hot standby supports up to 4 modules)
implementation of up to four)
Supports extended diagnostic data, alarm indication and acknowledgement processing, multicast and broadcast messaging (DPV1)
Configuration
ProSoft Configuration Builder (PCB) provides a PC-based software configuration solution for managing module configuration files and viewing communications and network diagnostics.
The PCB is a powerful solution not only for new configuration files, but also for importing configuration information from previous installations (known jobs) into new projects.
General Specifications
– Single slot – Quantum backplane compatible
– Module is recognised as an option module with access to PLC memory
for data transfer
– Configuration data is stored in the ProTalk® module’s non-volatile memory
– Microsoft Windows XP, 2000 and NT configuration software included with module
– Up to six modules can be placed in a rack
– Local rack – modules must be placed in the same rack as the processor
– Compatible with all common quantum programming software packages, including Concept
(version 2.6 or later), Unity Pro (version 2.2 or later), ProWORX (version 2.20 or later) (HSHS)
or higher) (HSBY for Unity Pro environments only)
– Quantum data types supported: 3x, 4x
– High-speed data transfer on the backplane provides fast data update times
– Sample ladder files available
Functional Specifications
– Easy-to-use bus view drag-and-drop configuration interface via ProSoft
Configuration Builder software (see PSW-PCB datasheet)
– Monitors and modifies process data and DPV1 acyclic data, and provides online slave diagnostics
– Supports PROFIBUS PA slaves on the network via DP/PA coupler or link
– Supports up to 125 slave devices via repeaters
– Supports extended diagnostic data (DPV1)
– Supports all standard baud rates up to 12 Mbits/s
– Automatic baud rate detection at all valid PROFIBUS DPV1 rates
– Supports parameter read/write operations according to PROFIdrive 3.1 standard
– Supports synchronisation and freeze commands
– Alarm indication and acknowledgement processing (DPV1)
– Support for multicast and broadcast messages (DPV1)
– Conformity of the slave configuration to the processor determined by CRC checksums
– Includes FDT/DTM PROFIBUS master transport communication DTM software (part number PSW-CDTM-PDPM)
Hot Standby
– Hot standby function supports SE 140 671 CPUs
– Supports up to six PTQ-PDPMV1 hot standby modules per rack
– Provides health status for active master and passive
Auxiliary master health status
– PROFIBUS switchover time of 100 ms nominal, not to exceed 300 ms
– Cable break detection via segmented network slave count information
– Generation of PROFIBUS health information from the secondary master via FDL ping service
– No setup parameters are required. Module automatically detects hot standby system Physical characteristics
– PROFIBUS DPV1 RS-485 interface with 9-pin D-type female connector and isolated optocoupler
– Master LED status indicators for operation, network out of communication, and master token hold state